Post Jobs

ASTM B557 PDF

Methods B , and are compatible in technical content except for the requirement 1 These test methods are under the jurisdiction of ASTM Committee B07 on. 1 Jan Buy ASTM B TEST METHODS FOR TENSION TESTING WROUGHT AND CAST ALUMINUM- AND MAGNESIUM-ALLOY. ASTM B tension test of cast aluminum magnesium test methods cover the tension testing of wrought and cast aluminum- and magnesium-alloy products.

Author: Fegor Sataur
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Relationship
Published (Last): 18 July 2018
Pages: 238
PDF File Size: 17.13 Mb
ePub File Size: 9.56 Mb
ISBN: 484-6-88352-915-3
Downloads: 27978
Price: Free* [*Free Regsitration Required]
Uploader: Mazukinos

A high-capacity universal testing machine that conforms to the requirements of Practices E4 should be astn to conduct this test. Measure the cross-sectional dimensions of the specimen and mark the gauge length. Link to Active This link will always route to the current Active version of the standard.

ASTM B557 Tension Cast Aluminum Magnesium Test Equipment

Have a question about conducting the test for this standard? The ASTM B information may be useful in comparisons of materials, alloy development, quality control, and design under certain circumstances. ASTM B provides information on the strength and ductility of materials under uniaxial tensile stresses. ASTM B tension test of cast aluminum magnesium test methods cover the tension testing of wrought and cast aluminum- and magnesium-alloy products, except aluminum foil, and are derived from test methods ASTM E8, which cover the tension testing of all metallic materials.

Sheet products in this thickness range are supplied to sheet product specifications and foil products in this thickness range are supplied to foil product specifications.

Force range of 5 kN to kN 1, lbf tolbf Adjustable test space The most popular choice for static tension and compression tests These dual column testers are available in both tabletop and floor standing models.

Try This PDF:   DURNIU LAIVAS PDF

ASTM B is a testing standard that covers the tension testing requirements of wrought and cast aluminum- and magnesium-alloy products, excepting aluminum foil see test method Axtm for aluminum foil test requirements. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. The results of ASTM B tension tests of specimens machined to standardized dimensions from selected portions of a part or material may represent the strength and ductility properties of the entire end product or its in-service behavior in different environments.

Load the specimen into your tensile grips. Work with us to find the right b5557 for your ASTM standard. Historical Version s – view previous versions of standard.

A complete metric companion to Test Methods B has been axtm Methods BM ; therefore, no metric equivalents are presented in these test methods. No other units of measurement are included in this standard. Rectangular, round or pin-loaded specimens may be used.

How to Perform ASTM B Aluminum and Magnesium Alloy Tension Testing – ADMET

Refer to the recommended dimensions tables for each sample type in the publication. Load ratings from 25 kN to kN 5, lbf tolbf Jaws move laterally in stationary position while grip body moves on adjustment Works well with round or flat specimens. Historical Version s – view previous versions of standard Translated Version g557 Give our test engineers a call today for help configuring the best test machine and ashm according to your standard. We are confident that we have what you are looking for.

Exceptions to the provisions of these test methods may need to be made in individual specifications or test methods for a particular material. Unless otherwise specified, any convenient speed of testing may be used up to one half the specified yield strength, or up to one quarter the specified tensile strength, whichever adtm smaller.

Try This PDF:   SEW EURODRIVE GEAR MOTOR CATALOG EBOOK

By means of our testing expertise and modular product design, we will help find the solution that is right for you. Sales Support Calibration Calculators.

The speed may be increased after the removal of extensometer, but it should not exceed 0. Apply b55 load and begin grip separation. This method determines the strength and ductility of materials under uniaxial tensile stresses. Although various types of grips can be used for gripping the samples, the recommended grips are wedge grips with serrated inserts.

How to Perform ASTM B557 Aluminum and Magnesium Alloy Tension Testing

Foil is sheet metal less than 0. We are happy to help!

Remove the extensometer prior to specimen fracture. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications. There is an overlap in the thickness range 0. The ASTM B test methods b57 considered satisfactory for acceptance testing of commercial shipments and have been used extensively in the trade for this purpose.

Attach the clip-on extensometer for strain calculations. This information may be useful in comparisons of materials, alloy development, quality control, and design under certain circumstances. To determine the elongation after fracture, fit ends wstm the fractured specimen together and measure the distance between the initial gauge marks.